MIL-HDBK-1003/1
(5) service sinks 1 per floor.
j For "High hazard" occupancies involving exposure to skin contamination with poisonous, infectious, or irritating materials, provide fixtures per note i. "Business" above, except provide lavatories at 1 per 5 persons.
k For "Assembly - Stadiums, pools, etc." add a new line for Locker rooms (for athletes, not spectators). Provide fixtures per note i. "Business" above."
SECTION 411.3 Add the following: "Refer to Appendix H for additional requirements for use on Navy projects."
SECTION 412.4 Required Location and Construction. Add the following: "Floor drains are not required in service sink rooms and transformer rooms. Provide floor drains to serve, but not be limited to, the following areas and equipment:
1. Gang toilets, which are those having three or more water closets; and gang shower drying rooms, which are those serving two or more showers.
2. Subsistence buildings, as follows:
(a) Dish-washing, scullery or pot-washing, and food-cart washing areas.
(b) Vegetable peelers and vegetable preparation areas. (c) Steam table and coffee urn areas.
(d) Soda fountain area.
(e) Adjacent areas to ice chests, ice-making machines, and walk-in, reach-in, and garbage refrigerators.
(f) Steam cookers and steam-jacketed kettles.
3. Cold-storage buildings are as follows:
(a) Fat-rendering, processing, salvage, and receiving rooms.
(b) Receiving and issuing vestibules.