MIL-HDBK-1036A
3.8.11 Game Room. Provide a room acoustically isolated as appropriate, with appropriate electrical outlets, and close to public toilets. Design for installation of electronic video games. Locate for appropriate monitoring by bachelor housing personnel. Finishes should be easily cleaned, and endure hard
use and food spills. This can be considered an optional feature.
3.8.12 Vending Area. Provide vending space with appropriate outlets. Allow space for ice dispenser, and soft drink and food vending machines, at least one 460 millimeter diameter waste receptacle, and at least one 765 millimeter diameter recycling container. Locate space for security of users and for ease of service. Provide appropriate sound isolation between vending and other spaces. Recess the machines into the wall or provide treatment area to give a recessed appearance. Provide an
accented floor surface and a dropped ceiling with open grid type panels or acoustic tiles to accent the vending area. Drop the soffit above the machines to the top of the machines. Coordinate paint or wall covering with the interior designers concept of the facility. Mirrored panels, cove lighting, and neon lights are optional. Floor and base finishes should resist heavy wear and
be easily cleaned. Discuss vending area requirements, and machine quantity and type at the activity level.
3.8.13 Public Toilets. Provide public toilets accessible from the lobby and the public areas. Provide commercial grade fixtures. Provide a minimum of one water closet, one urinal, and two sinks in the men's toilet; two water closets, two sinks in
the women's toilet for a 96 personnel project. Add one of each fixture for each personnel increment of 100 to a maximum of five toilets. Public toilets must be accessible to disabled persons. Provide overhead lighting and light at the lavatory mirror. Provide floor and wall finishes as described in Table 2. Use solid surfacing material for lavatory counters and solid plastic, continuous anchorage toilet partitions. Provide a floor drain placed out of the usual traffic pattern and close to the water closets. Include dispensers for soap, towels, toilet tissue, and waste receptacle.
3.8.14 Supply Storage Room. Provide one secure space of about
23 sq. m. net area for housekeeping equipment and supplies.
Finish floor, base, and wall at the mop receptor to resist water.
Quarry tile or ceramic tile are examples of acceptable finishes.
Provide motion-activated light.
32